Skip to content

Direct Factory · Shandong, China · 10-100 mm PU & EPS · CNAS Class B1 Tested · Free Cut Samples

Menu

THERMAL & BURNING CLASSIFICATION | GB 8624-2012 CLASS B1

Class B1 Fire-Retardant & Heat-Resistant Wall Panels

Flame-retardant PU (31.2% oxygen index) and EPS (30.8% oxygen index) metal-faced wall panels tested to Class B1 (D-s1, d0) under GB 8624-2012, paired with 0.020 W/(m.K) thermal insulation against summer solar heat.

  • Class B1 (D-s1, d0) burning classification under GB 8624-2012 (TECC CNAS L23527)
  • Tested oxygen index 31.2% (PU) and 30.8% (EPS) under GB/T 2406.2
  • Full 10-page stamped CNAS / ilac-MRA bilingual fire & thermal dossier available on request

Direct Factory · Shandong, China · 10-100 mm PU & EPS · CNAS Class B1 Tested · Free Cut Samples

On this page

Verified burning & thermal performance (TECC CNAS Report ZJTB3307037563GR)

Our flame-retardant PU and EPS insulated wall panels are independently tested by an ilac-MRA / CNAS-accredited laboratory (Hunan TECC Report ZJTB3307037563GR) for Class B1 (D-s1, d0) burning behavior, oxygen index, and thermal conductivity.

Test metricPU Core PanelEPS Core PanelTest Standard
Burning classificationClass B1 (D-s1, d0)Class B1 (D-s1, d0)GB 8624-2012
Core oxygen index (OI)31.2% (req >= 30%)30.8% (req >= 30%)GB/T 2406.2
Thermal conductivity (25 C)0.020 W/(m.K)0.033 W/(m.K)GB/T 23932-2025 / GB/T 10801.1-2025
Outer face materialNon-combustible Al-Zn steelNon-combustible Al-Zn steelGB/T 2518-2019
Heat reflection layerRear aluminum foil clothRear aluminum foil clothStandard 3-layer construction

Thermal protection & Class B1 flame-retardant construction

On detached houses, villas, garden offices, farm buildings, modular cabins, and exterior renovations, flame-retardant Class B1 PU metal siding slows heat transfer sharply in summer (0.020 W/m.K closed-cell foam + reflective foil backing) while shielding the insulation core behind a non-combustible Al-Zn steel exterior skin.

With oxygen index ratings above 30% (31.2% PU / 30.8% EPS) and a continuous interlocking metal face, panels self-extinguish once external flame sources are removed. For commercial specifications or engineering submittals, request our full stamped bilingual TECC test dossier or matched batch test specimens.

Factory QC technician verifying 16.16 mm thickness on flame-retardant PU insulated panel with digital caliper

Direct manufacturing in Shandong — verified numbers

Jinan Jiye Building Materials Co., Ltd. runs continuous one-step panel forming lines at our Zouping, Binzhou plant. Every panel ships with traceable coil batch records and stamped CNAS lab data.

10–100 mm

PU & EPS core thicknesses (383 mm cover width)

0.020 W/m·K

CNAS-tested PU thermal conductivity at 25°C

100+ Finishes

Embossed wood, brick, stone & fluted coil stock

3,800 m²

Max 16 mm panel loading per 40HQ container

Workshop checkpoints buyers ask to see

From pre-painted Al-Zn coil staging to double-belt curing and export container stuffing, our production line handles panels and matching trims under one roof.

Pre-painted wood grain, stone, and solid color Al-Zn steel coils staged in the factory warehouse

Coil inventory & embossing rollers

Pre-painted Al-Zn alloy steel coils (0.21 mm, 0.23 mm, and 0.27 mm) and 304 stainless steel stock feed dedicated brick, wood grain, fluted, and stone roller dies. Tested coating mass: 105 g/m2 front Al-Zn (min point 92 g/m2). Steel gauges: 0.21 / 0.23 / 0.27 mm (customizable).

Double-belt heating and laminating curing line for PU insulated metal panels

Double-belt heating & curing

Heated laminating belts hold panel flatness while the PU foam expands and bonds to both the embossed steel face and the moisture-barrier foil backing. Measured bond strength: 0.16 MPa (PU) / 0.15 MPa (EPS). Dimension tolerance: Length -1 mm, width +1 mm, thickness +0.5 mm.

Export cartons of insulated metal siding hand-loaded neatly inside an ocean container

Carton packing & container loading

Standard 16 mm panels pack 10 pieces per labeled export carton (4000 x 420 x 160 mm for 4 m boards) or cut to 2.9 m / 3.8 m / 5.8 m lengths to optimize container cube. 20GP capacity (16 mm): Approx. 1,300 to 1,500 m2. 40HQ capacity (16 mm): Approx. 3,200 to 3,800 m2.

Third-party CNAS / ilac-MRA test summary (Report ZJTB3307037563GR)

Independently measured by Hunan TECC Testing Co., Ltd. (CNAS L23527 / ilac-MRA accredited) on July 10, 2026 using 0.21 mm Al-Zn faced exterior wall panels under GB/T 23932-2025, JG/T 287-2013, and GB 8624-2012. Full 10-page stamped bilingual PDF report available on request.

Test itemPU core resultEPS core resultReference standard
Apparent core density43 kg/m3 (req >= 38)22 kg/m3 (req >= 18)GB/T 23932-2025 / GB/T 10801.1-2025
Thermal conductivity at 25 C0.020 W/(m.K) (req <= 0.024)0.033 W/(m.K) (req <= 0.039)GB/T 23932-2025 / GB/T 10801.1-2025
Compressive strength152 kPa (req >= 120)118 kPa (req >= 100)GB/T 23932-2025
24 h volume water absorption2.4% (req <= 4.0%)2.1% (req <= 3.5%)GB/T 23932-2025 / GB/T 10801.1-2025
Metal-to-core bond strength0.16 MPa (core failure)0.15 MPa (core failure)JG/T 287-2013
Burning classification & oxygen indexClass B1 (D-s1, d0) / OI 31.2%Class B1 (D-s1, d0) / OI 30.8%GB 8624-2012 / GB/T 2406.2
Coating adhesion & impactGrade 1 / 500 g ball @ 500 mm intactGrade 1 / 500 g ball @ 500 mm intactJG/T 287-2013
Acid & alkali resistance (48 h)No peeling, blistering, or rustNo peeling, blistering, or rustGB/T 2518-2019 (5% HCl & 5% NaOH)

Common buyer questions

What fire-retardant rating do Jiye insulated metal wall panels achieve?

Both our flame-retardant PU core (oxygen index 31.2%) and EPS core (oxygen index 30.8%) achieved Class B1 (D-s1, d0) burning classification under GB 8624-2012 in Hunan TECC CNAS / ilac-MRA Report ZJTB3307037563GR, backed by a non-combustible Al-Zn steel outer face.

Can we receive the official laboratory test report and batch test samples for project submittals?

Yes. Contact our export desk to download the full 10-page stamped bilingual Hunan TECC PDF dossier. For commercial projects requiring local laboratory submissions, we also supply matched production-batch test specimens on request.

How well do the panels block summer heat?

Rigid PU measured 0.020 W/(m.K) thermal conductivity at 25 C paired with a reflective rear aluminum foil cloth, slowing radiant and conductive heat transfer across exterior walls.

Request the full TECC Class B1 test report

Tell us your building type and destination country so we can send the bilingual CNAS report PDF.

Get a quoteWhatsApp