CORROSION-RESISTANT SPECIALTY CLADDING
304 Stainless Steel Insulated Wall Panels
Insulated wall panels faced with 304 stainless steel laminated onto rigid PU or EPS foam. Built for coastal salt-spray exposure, food-adjacent utility walls, humid workshops, and clean architectural facades where painted steel is not enough.
- 304 stainless steel exterior face for coastal salt-air & high-humidity environments
- Bonded to rigid closed-cell PU insulation with foil moisture barrier backing
- Custom thickness and cut-to-length production directly from our continuous line
Direct Factory · Shandong, China · 10-100 mm PU & EPS · CNAS Class B1 Tested · Free Cut Samples

On this page

When to upgrade from Al-Zn coated steel to 304 stainless steel
Pre-painted Al-Zn steel (measured at 105 g/m2 coating mass in our TECC lab test) handles standard inland residential and commercial weather well. However, buildings within a few kilometers of sea spray – such as Mediterranean coastal villas in Italy, North Sea coastal sites in the Netherlands, or washdown industrial rooms – expose cut edges and fastener zones to aggressive chloride corrosion.
Switching the outer skin to 304 stainless steel keeps the same lightweight 383 mm interlocking panel format and rigid PU thermal core while removing painted-coating chalking and cutting long-term rust risk.
304 stainless steel face vs. pre-painted Al-Zn steel face
| Comparison point | 304 Stainless Steel Face | Pre-Painted Al-Zn Steel Face |
|---|---|---|
| Corrosion environment | Coastal salt air, chemical splash, humid washdown rooms | Standard inland residential, commercial, and rural weather |
| Visual finish | Brushed / metallic stainless appearance | 100+ wood, brick, stone, marble, and solid color coatings |
| Core & thickness range | Rigid PU or EPS | 16 mm to 100 mm | Rigid PU or EPS | 10 mm to 100 mm |
| Production lead time | Made to order (coil MOQ applies) | Stock patterns ready fast; custom coils to order |
| Matching fasteners | Use 304/316 stainless self-drilling screws | Galvanized or stainless exterior screws |
Direct manufacturing in Shandong — verified numbers
Jinan Jiye Building Materials Co., Ltd. runs continuous one-step panel forming lines at our Zouping, Binzhou plant. Every panel ships with traceable coil batch records and stamped CNAS lab data.
10–100 mm
PU & EPS core thicknesses (383 mm cover width)
0.020 W/m·K
CNAS-tested PU thermal conductivity at 25°C
100+ Finishes
Embossed wood, brick, stone & fluted coil stock
3,800 m²
Max 16 mm panel loading per 40HQ container
Workshop checkpoints buyers ask to see
From pre-painted Al-Zn coil staging to double-belt curing and export container stuffing, our production line handles panels and matching trims under one roof.

Coil inventory & embossing rollers
Pre-painted Al-Zn alloy steel coils (0.21 mm, 0.23 mm, and 0.27 mm) and 304 stainless steel stock feed dedicated brick, wood grain, fluted, and stone roller dies. Tested coating mass: 105 g/m2 front Al-Zn (min point 92 g/m2). Steel gauges: 0.21 / 0.23 / 0.27 mm (customizable).

Double-belt heating & curing
Heated laminating belts hold panel flatness while the PU foam expands and bonds to both the embossed steel face and the moisture-barrier foil backing. Measured bond strength: 0.16 MPa (PU) / 0.15 MPa (EPS). Dimension tolerance: Length -1 mm, width +1 mm, thickness +0.5 mm.

Carton packing & container loading
Standard 16 mm panels pack 10 pieces per labeled export carton (4000 x 420 x 160 mm for 4 m boards) or cut to 2.9 m / 3.8 m / 5.8 m lengths to optimize container cube. 20GP capacity (16 mm): Approx. 1,300 to 1,500 m2. 40HQ capacity (16 mm): Approx. 3,200 to 3,800 m2.
Third-party CNAS / ilac-MRA test summary (Report ZJTB3307037563GR)
Independently measured by Hunan TECC Testing Co., Ltd. (CNAS L23527 / ilac-MRA accredited) on July 10, 2026 using 0.21 mm Al-Zn faced exterior wall panels under GB/T 23932-2025, JG/T 287-2013, and GB 8624-2012. Full 10-page stamped bilingual PDF report available on request.
| Test item | PU core result | EPS core result | Reference standard |
|---|---|---|---|
| Apparent core density | 43 kg/m3 (req >= 38) | 22 kg/m3 (req >= 18) | GB/T 23932-2025 / GB/T 10801.1-2025 |
| Thermal conductivity at 25 C | 0.020 W/(m.K) (req <= 0.024) | 0.033 W/(m.K) (req <= 0.039) | GB/T 23932-2025 / GB/T 10801.1-2025 |
| Compressive strength | 152 kPa (req >= 120) | 118 kPa (req >= 100) | GB/T 23932-2025 |
| 24 h volume water absorption | 2.4% (req <= 4.0%) | 2.1% (req <= 3.5%) | GB/T 23932-2025 / GB/T 10801.1-2025 |
| Metal-to-core bond strength | 0.16 MPa (core failure) | 0.15 MPa (core failure) | JG/T 287-2013 |
| Burning classification & oxygen index | Class B1 (D-s1, d0) / OI 31.2% | Class B1 (D-s1, d0) / OI 30.8% | GB 8624-2012 / GB/T 2406.2 |
| Coating adhesion & impact | Grade 1 / 500 g ball @ 500 mm intact | Grade 1 / 500 g ball @ 500 mm intact | JG/T 287-2013 |
| Acid & alkali resistance (48 h) | No peeling, blistering, or rust | No peeling, blistering, or rust | GB/T 2518-2019 (5% HCl & 5% NaOH) |
Questions on 304 stainless steel insulated panels
Can 304 stainless steel panels be used inside food prep or washdown utility rooms?
Yes. The 304 stainless steel face paired with rigid closed-cell PU foam delivers a washable, corrosion-resistant wall surface suited to coastal facades, utility rooms, food-prep spaces, and humid workshops. Share your joint detailing or specification sheet and our team will match the skin gauge, thickness, and trim set.
What screws and trims should we pair with 304 panels?
Always use stainless steel fasteners and matching stainless or coated aluminum trim channels to avoid galvanic corrosion between dissimilar metals in damp air.
Inquire about 304 stainless steel panel MOQ and pricing
Share your required thickness, panel length, quantity in m2, and operating environment.