POLYURETHANE (PU) & EPS CORES | 10 MM TO 100 MM
PU & EPS Insulated Sandwich Wall Panels (16-100 mm)
Embossed metal-faced thermal insulation panels manufactured with either rigid polyurethane foam (0.020 W/m.K) or molded EPS polystyrene (0.033 W/m.K) across 10 mm to 100 mm thicknesses.
- PU core (0.020 W/m·K, 43 kg/m³) & EPS core (0.033 W/m·K, 22 kg/m³) CNAS verified
- Full thickness range from 16 mm lightweight cladding up to 100 mm insulated walls
- Factory-cut lengths reduce on-site scrap and optimize 20GP / 40HQ loading
Direct Factory · Shandong, China · 10-100 mm PU & EPS · CNAS Class B1 Tested · Free Cut Samples

On this page
Real factory thickness builds from 16 mm to 100 mm
Unlike factories locked into a single 16 mm die, our lines run stepped thickness profiles so you can specify decorative embossed finishes even on 30 mm, 50 mm, and 100 mm insulated walls.

16 mm – 25 mm Decorative PU Panels
High-density 43 kg/m3 rigid PU core maximizing container loading volume (up to 3,800 m2 per 40HQ in 16 mm) for facade refresh, cabins, and prefab buildings.
PU lambda (25 C) 0.020 W/(m.K) (TECC CNAS)
Weight (16 mm) 3.7 kg/m2

30 mm Embossed Insulated Panels
Mid-range thermal wall board combining full brick, wood, or stone exterior embossing with nearly double the insulation thickness of standard 16 mm siding.
Core options Rigid PU or Molded EPS
Cover width 383 mm interlocking

50 mm Heavy-Insulation Wall Panels
Built for colder European winters, commercial enclosures, and residential retrofits where meaningful U-value reduction is needed alongside a finished exterior face.
Core options PU (152 kPa) or EPS (118 kPa)
Fire test Class B1 (D-s1, d0) GB 8624-2012

75 mm – 100 mm High-R Panels
Maximum insulation thickness for cold-climate workshops, agricultural buildings, and temperature-controlled rooms that still need a clean stone or metallic outer skin.
Thermal focus Cold storage, alpine & northern builds
Cut length Custom up to container limit
PU core vs. EPS core – verified lab comparison (TECC CNAS ZJTB3307037563GR)
Both cores were tested on 0.21 mm Al-Zn faced exterior wall panels in July 2026. Choose PU when wall thickness is tight and you want maximum insulation per millimeter; choose EPS when thicker walls (50-100 mm) are acceptable and unit material cost is the main driver.
| Measured property | Rigid PU Core | Molded EPS Core | What changes for the buyer |
|---|---|---|---|
| Apparent core density | 43 kg/m3 | 22 kg/m3 | PU feels firmer under thumb pressure and resists face denting better |
| Thermal conductivity (25 C) | 0.020 W/(m.K) | 0.033 W/(m.K) | PU delivers ~65% better insulation at the exact same thickness |
| Compressive strength | 152 kPa | 118 kPa | Higher load stability around fastener lines on PU |
| 24 h water absorption | 2.4% | 2.1% | Both stay well below the 4.0% / 3.5% standard limits |
| Metal-to-core tensile bond | 0.16 MPa | 0.15 MPa | Both broke inside the foam core rather than peeling off the steel |
| Oxygen index & burning class | 31.2% | Class B1 | 30.8% | Class B1 | Flame-retardant cores per GB 8624-2012 / GB/T 2406.2 |
| Typical budget role | Best in 16-50 mm walls | Cost-effective in 50-100 mm walls | EPS saves budget on thick builds where space is not tight |
Direct manufacturing in Shandong — verified numbers
Jinan Jiye Building Materials Co., Ltd. runs continuous one-step panel forming lines at our Zouping, Binzhou plant. Every panel ships with traceable coil batch records and stamped CNAS lab data.
10–100 mm
PU & EPS core thicknesses (383 mm cover width)
0.020 W/m·K
CNAS-tested PU thermal conductivity at 25°C
100+ Finishes
Embossed wood, brick, stone & fluted coil stock
3,800 m²
Max 16 mm panel loading per 40HQ container
Workshop checkpoints buyers ask to see
From pre-painted Al-Zn coil staging to double-belt curing and export container stuffing, our production line handles panels and matching trims under one roof.

Coil inventory & embossing rollers
Pre-painted Al-Zn alloy steel coils (0.21 mm, 0.23 mm, and 0.27 mm) and 304 stainless steel stock feed dedicated brick, wood grain, fluted, and stone roller dies. Tested coating mass: 105 g/m2 front Al-Zn (min point 92 g/m2). Steel gauges: 0.21 / 0.23 / 0.27 mm (customizable).

Double-belt heating & curing
Heated laminating belts hold panel flatness while the PU foam expands and bonds to both the embossed steel face and the moisture-barrier foil backing. Measured bond strength: 0.16 MPa (PU) / 0.15 MPa (EPS). Dimension tolerance: Length -1 mm, width +1 mm, thickness +0.5 mm.

Carton packing & container loading
Standard 16 mm panels pack 10 pieces per labeled export carton (4000 x 420 x 160 mm for 4 m boards) or cut to 2.9 m / 3.8 m / 5.8 m lengths to optimize container cube. 20GP capacity (16 mm): Approx. 1,300 to 1,500 m2. 40HQ capacity (16 mm): Approx. 3,200 to 3,800 m2.
Third-party CNAS / ilac-MRA test summary (Report ZJTB3307037563GR)
Independently measured by Hunan TECC Testing Co., Ltd. (CNAS L23527 / ilac-MRA accredited) on July 10, 2026 using 0.21 mm Al-Zn faced exterior wall panels under GB/T 23932-2025, JG/T 287-2013, and GB 8624-2012. Full 10-page stamped bilingual PDF report available on request.
| Test item | PU core result | EPS core result | Reference standard |
|---|---|---|---|
| Apparent core density | 43 kg/m3 (req >= 38) | 22 kg/m3 (req >= 18) | GB/T 23932-2025 / GB/T 10801.1-2025 |
| Thermal conductivity at 25 C | 0.020 W/(m.K) (req <= 0.024) | 0.033 W/(m.K) (req <= 0.039) | GB/T 23932-2025 / GB/T 10801.1-2025 |
| Compressive strength | 152 kPa (req >= 120) | 118 kPa (req >= 100) | GB/T 23932-2025 |
| 24 h volume water absorption | 2.4% (req <= 4.0%) | 2.1% (req <= 3.5%) | GB/T 23932-2025 / GB/T 10801.1-2025 |
| Metal-to-core bond strength | 0.16 MPa (core failure) | 0.15 MPa (core failure) | JG/T 287-2013 |
| Burning classification & oxygen index | Class B1 (D-s1, d0) / OI 31.2% | Class B1 (D-s1, d0) / OI 30.8% | GB 8624-2012 / GB/T 2406.2 |
| Coating adhesion & impact | Grade 1 / 500 g ball @ 500 mm intact | Grade 1 / 500 g ball @ 500 mm intact | JG/T 287-2013 |
| Acid & alkali resistance (48 h) | No peeling, blistering, or rust | No peeling, blistering, or rust | GB/T 2518-2019 (5% HCl & 5% NaOH) |
Deep-dive guides on core and thickness selection
Quote PU or EPS insulated wall panels by thickness
Specify core type (PU or EPS), thickness (16-100 mm), steel skin gauge, quantity in m2, and destination port.